Table of Contents Table of Contents
Previous Page  40 / 266 Next Page
Information
Show Menu
Previous Page 40 / 266 Next Page
Page Background

40 2014 Registration Document

Social responsibility

2

Action plans

◗

Implementing an Energy Management System

(ISO 50001)

In early 2014, the Group, by implementing an efficient energy management

system in partnership with all parties involved and raising awareness

among all its employees, became the first French retailer to obtain

ISO 50001 certification for all its consolidated sites: stores, warehouses

and head offices. Carrefour’s goal is to take this approach even further

by adopting a specific management system for controlling energy

consumption for each format.

KEY FIGURES

In 2014, the energy consumption (electricity, fuel and

gas) of the Group’s stores dropped by

31.1

% (compared

with 2004 levels, perm

2

of sales area)

Goal achieved:

30

% reduction by 2020 compared with

2004 per m

2

of sales area

BREAKDOWN OF STORE ENERGY CONSUMPTION

Electricity

87.3%

Gas

10.3%

Fuel

2.4%

AVERAGE ELECTRICITY CONSUMPTION IN HYPERMARKETS

Food refrigeration

35%

Air conditioning

25%

Lighting

24%

Food preparation and other areas

16%

Average consumption from a survey.

CHANGE IN STORE ENERGY CONSUMPTION

2014

2013

2012

% vs. 12

Energy consumption – Electricity, Gas and Fuel

(in kg/m

2

of sales area)

552.0

572.2

582.6

(5.2)%

Like-for-like BUs (scope: 100% of 2014 consolidated sales, excl. VAT).

5

2014 figures verified with a result of reasonable assurance.

◗

Reducing emissions from cooling

Refrigerants used to run the positive and negative refrigeration systems

represent the second-largest source of greenhouse gas emissions

generated by the stores’ activity. To reduce these emissions, the Carrefour

group launched a strategy composed of three phases aiming to:

■

reduce consumption of refrigerant fluids in particular by identifying

and reducing leaks, with the goal of limiting them to 10% of the gas

used in its facilities;

■

eliminate hydrofluorocarbons fluids (HFC): Carrefour has also pledged

to stop using HFC fluids in its new cooling facilities as of 2015 in the

majority of its stores in Europe;

■

gradually equip the Group with closed refrigeration units that can

run on natural fluids.

The Group has launched a diagnostic analysis aimed at measuring fluid

leak rates and identifying their causes so as to introduce corrective

measures. Between 2012 and 2014, the quantity of refrigerant gas

refilled in cooling and air conditioning facilities following leaks dropped

by 4% per m

2

of sales area.

Carrefour is developing alternative systems that use natural fluids like

carbon dioxide (CO

2

), which have a lower impact on climate change and

the ozone layer. Moreover, CO

2

requires very tightly-sealed refrigeration

facilities which significantly reduce leaks. The new-generation equipment

consumes both less fluid and 10% to 20% less electricity.

After the first conclusive tests, when replacements were needed the

Group began to gradually convert facilities that ran on fluorinated fluids

to ones that use scalable mixed CO

2

solutions or 100%CO

2.

This makes

Carrefour a pioneer in its European countries, having rolled out natural

solutions to 170 stores in seven countries as of the end of 2014. Roll-

out of the solution in Brazil also began in 2014, with three stores now

equipped with hybrid systems.

The Group is also developing a fully-integrated air conditioning solution,

which consists of producing cold at a single point for both air conditioning

and food refrigeration. This technique allows stores to eliminate their

consumption of chemical fluids and reduce their energy consumption. A

test took place in Italy in 2014, and three more are planned for Belgium

and France.

2014

2013

2012

% vs. 12

Quantity of refrigerant refilled due to leakage

(kg/1,000m

2

of sales area)

48.7

47.7

50.8

(4.2)%

Like-for-like BUs (scope: 96% of 2014 consolidated sales, excl. VAT) - excluding: HM: AR/SM: AR.