Table of Contents Table of Contents
Previous Page  537-Permit To Work / 748 Next Page
Information
Show Menu
Previous Page 537-Permit To Work / 748 Next Page
Page Background

P

er

m

it to

W

or

k

BOS-PRD-03.900902

x

A lifebuoy with suitably long lifeline

shall

be readily available at the work site. It is also advisable to

float another life-buoy in the water adjacent to the work area for immediate access if a person falls

into the water;

x

Any applicable authorities (

H

a

r

b

o

u

r M

as

ter

, etc.)

shall

be informed;

x

Engine

Wa

t

c

h O

ff

i

c

er

informed if any over-side/outboard work is to take place in the vicinity of any

overboard discharges;

x

As applicable, Lock-Out/Tag-Out instructions

shall

be followed.

4.1

2 E

le

c

tri

ca

l

sys

te

ms

A PTW is required for all work on electrical systems involving electric current greater than 50 volts in:

x

Electrical panels;

x

Cabinets including engine room, bridge and galley control panels;

x

Power circuits;

x

Switchboards;

x

Alternators.

The primary hazards associated with working on electrical systems are exposure to electrical current, burns,

and unexpected start-ups of equipment.

The Electrical Systems identifies necessary safety measures.

(PTW # 2 Electrical Isolation, BOS-FRM-

03.0021).

P

re

cau

tio

ns &

A

wa

re

n

e

ss

x

Be aware that even when an electrical or electronic unit is isolated, it may still have stored energy or

a secondary control feed into it that is not included in the main feed isolation box;

x

Identification and use of the correct Personal Protective Equipment (PPE);

x

Ensure that all relevant personnel are informed;

x

Lock-Out/Tag-Out

shall

be used to ensure applicable equipment is removed from service/isolated

from sources of power or heat;

x

It is necessary to ensure that the flow of energy (electricity) has been completely stopped and that

the system cannot cause injury;

x

For optimal safety the work area

shall

be cordoned off, warning notices posted and all personnel not

involved with the task kept clear.

4.1

3 P

re

ssu

ri

z

e

d

sys

te

ms (PTW

>

7 ba

r

s)

A PTW is required for work on systems involving the flow of fluids under 7 bars of pressure such as

hydraulic-powered equipment (winches, windlass, cranes, rotative brushes etc.)

(PTW # 5 Pressurised

Systems, BOS-FRM-03.0020)

.

The primary hazards associated with working on pressurised systems are exposure to pressurised fluid and

unexpected start-ups of equipment.

The Pressurised Systems PTW identifies the safety measures necessary.

P

re

cau

tio

ns &

A

wa

re

n

e

ss

x

Identification and use of the correct Personal Protective Equipment (PPE) according to PPE matrix;

(wear Safety Goggles)

x

Lock-Out/Tag-Out instruction

shall

be used to ensure equipment is removed from service/isolated

from sources of power or heat;

x

The de-pressuring system and all limitations is to be fully reviewed and understood by those

assigned to work on any pressurised system;

x

Gauges and other instruments (as applicable)

shall

be constantly monitored;

Version 04. Original date: 25/05/2012. Version date: 31/12/2014. Valid version only on QMS site. Uncontrolled document when printed.

Procedure prepared by: BOS QHSES Coordinator. Approved by: BOS QHSES Manager. Validated by: BOS Quality Representative.

13 / 17

537